Benutzer-Werkzeuge

Webseiten-Werkzeuge


fileformats:c3d

Unterschiede

Hier werden die Unterschiede zwischen zwei Versionen angezeigt.

Link zu dieser Vergleichsansicht

Beide Seiten der vorigen RevisionVorhergehende Überarbeitung
Nächste Überarbeitung
Vorhergehende Überarbeitung
Nächste ÜberarbeitungBeide Seiten der Revision
fileformats:c3d [2018/01/04 14:29] oliverfileformats:c3d [2018/01/04 14:55] oliver
Zeile 1: Zeile 1:
 +===== Vicon c3d file format =====
 +
 +**Mime Type:** application/c3d-vicon+trial
 +
 +**File Suffix:** .c3d 
 +
 The C3D file format ([[http://www.c3d.org|www.c3d.org]]) is a public domain, binary file format that is used in Biomechanics, Animation and Gait Analysis laboratories to record synchronized 3D and analog data. This component implements read routines for this format and also for the non standard extentions made by Vicon and used by Vicon Workstation and Nexus. Write routines are also available but not yet tested. The C3D file format ([[http://www.c3d.org|www.c3d.org]]) is a public domain, binary file format that is used in Biomechanics, Animation and Gait Analysis laboratories to record synchronized 3D and analog data. This component implements read routines for this format and also for the non standard extentions made by Vicon and used by Vicon Workstation and Nexus. Write routines are also available but not yet tested.
  
 The usage of the c3d format is not recommended due to its restrictions and the manifold of unspecified workarounds to overcome them. The usage of the c3d format is not recommended due to its restrictions and the manifold of unspecified workarounds to overcome them.
  
-Some examples:+**Some examples:** 
 +  * Vicon stores Events in a proprietary way in the parameter section. But this allows to store only 127/255 events. 
 +  * The count of timeseries is saved in one byte. This results that it also needs a workaround, if you want to save more e.g as the CLEVE model do. To manage this, additional parameters are defined: DESCRIPTIONS2, LABELS2, ... 
 +  * The length of the timeseries is restricted due to the fact that the number is saved as an INT16 or UINT16
  
-    Vicon stores Events in a prprietary way in the parameter section. But this allows to store only 127/255 events+**The following list reports the parameters' format which are not supported by Vicon products:** 
-    The count of timeseries is saved in one byteThis results that it also needs a workaround if you want to save more e.g as the CLEVE model do. To mange this additional parameters are definedDESCRIPTIONS2, LABELS2, ..+  * A null frequency (POINT:RATE) is impossible
-    The length of the timeseries is restricted due to the fact that it is saved as INT16 or UINT16+  The description of each point (POINT:DESCRIPTIONS) can't be empty. 
 +  * The description of each analog channel(ANALOG:DESCRIPTIONS) can't be empty
 +  The description of the parameter in the analysis (ANALYSIS:DESCRIPTIONS) can't be empty. 
 +  * The subject associated which each parameter in the analysis (ANALYSIS:SUBJECTS) can't be empty.
fileformats/c3d.txt · Zuletzt geändert: 2018/01/04 14:59 von oliver